PVC Pipes

PVC Pipes inside and outside the building are used for pipes laid to drain the water. PVC pipes  TS 275-1 EN 1326-1 standards DIN 19 531 due to the smooth inner and outer surfaces that do not allow the formation of deposits, bacteria produce odor making PVC pipes, it is used in terms of ecological, economical ideal and for safety.

Rigid PVC pipes and fittings made of PVC material is resistant to different weather conditions. Fireproof, PVC pipes it is the most preferred type of pipe construction sector thanks to its highly resistant and rigid structure.

PVC pipes

Physical Properties of PVC Fittings

1) Vicat Softening Temperature (min 79ºC) (EN 727)
2) Influence of temperature (150 ° C – 30 minutes)
a) The injection point around a radius of 15 times the thickness of the gap in the area, depth of the peeling or bubbles should not be more than 50% of the wall thickness at that point.
b) PVC pipes Ring length of the cracks of the housing wall thickness in a distance 10 times, should be no more than 50% of the wall thickness at that point.
c) PVC pipes opening in the connecting line should not exceed 50% of the thickness of the line.
d) PVC pipes 30% of the meat depth of peelings in any other area of the part thickness, while the height of the wall thickness It should not exceed 10%.

Mechanical Properties of Pvc Fittings

It must be in accordance with EN 1401-1 and TS 2171 standards. 
1) Impact Strength (TS prEN 12061)
2) mechanical strength or flexibility (EN 12256)

PVC Pipes Uses

Groundwater and surface water transport system in place (city, industrial areas, waste water systems) – The electricity and communication systems, – Drainage, sewage and waste discharge systems – Chemical and industrial plants are PVC Pipes used in pressurized lines.

Advantages of Pvc Pipes

– Transport and installation because it is lightweight and easy to use. – PVC pipes and fittings, non-flammable and non-flammable.
– Rust does not contaminate the rainwater. Long lasting and maintenance-free.
– Decay and corrosion resistant, leakproof.
– Pressure loss is low.
– The surface is smooth and shiny.
– There -high impact strength.
– Pressurized Additional parts are fully compatible.
– Broken Not provide impact resistance as determined by the standard by more than 400%. -It shows high resistance to chemical inputs. -It Provides comfort by generating less noise. It does not react with the mineral diameter shrinks. Below -0 ° C, ice crack elastic structure.

PVC Material and Features

More than 50% of the product produced by PVC raw materials are used in the building industry in the world. PVC raw materials through environmentally friendly feature that does not appear to breaking events.
PVC raw material is also used in PVC pipes water color, smell and taste does not change, it does not harm human health. In the absence of filler material retains its original state. In fluid flows, especially in the vertical line it does not produce high levels of sound like the rigid pipes.
PVC raw materials is a raw material that is white has many positive features, historical development and many other details can be found PVC Pipes page.
PVC-U pipes and fittings produced in BD application class thickness (B and BD mark) is used for the following purposes; – Hot and cold domestic wastewater – Ventilation systems for domestic wastewater lines, – Building rainwater supplies; What is the difference in waste water and pressure systems between PP and PVC? The main difference between PVC and PP; Hardness is the subject.
PVC pipes superior in terms of hardness, which is more resistant than PP material in underground applications. But PVC PP in accordance temperature impact strength and also lower. In terms of flammability PP pipes in PVC pipe while burning flame burning as would be in the form of soot formation.

PVC Pipes are Fireproof

DIN 4102 PVC pipes have flammable UL94 standard produced by American standards, produced from hard PVC raw materials are defined as V-0. Length and diameter of PVC pipes

PVC Pipes Laying Rules

• Carefully laying the pipeline have started laying pipe life and improves quality. This is the base of the trench dug before the pipe laying operation must therefore be considered to be flat and stone free.
• Before laying the pipes filling quantity type of soil, depending on the season and climate should be between 1-1.5 meters.
• base will be poured into the ditch should be placed near the bed with 15 cm of sand and can be hard to stop the pipe.
• Check made the testing process which will be installed to seal the seams.
• PVC pipes and fittings in muff bed, a damaged condition must be determined in the case of extreme and should not be used.
• PVC pipes and fittings will be made in each assembly should be applied to the ends of liquid soap for an easy installation.
• Any iron clamps should be used except in PVC pipes, steel etc. should not be material.
• After closing the floor if it is performed with the top of the PVC pipes should be laid on top of her sand off the ground.
• In winter the pipes and fittings should be avoided, especially from shock.